Steam Superheaters
Industrial plants need superheated steam either for steam networks at various pressures (low, medium and high-pressure steam) or directly, for various different processes.
SELAS-LINDE builds steam superheaters to suit customers' requirements for all pressure ranges from low-pressure to high-pressure steam.
| Underfired heat: |
|
up to 50 MW |
| Process pressures: |
|
up to 50 bar |
| Steam superheating temperatures: |
|
up to 870°C |
| NOx emissions: |
|
< 200 mg/Nm³ |
| Furnace type: |
|
Box furnace with preheating in a convection zone above it |
| Firing: |
|
Bodenfeuerung, Naturzug oder Zwangsluft |
| Tube coils: |
|
Multipass bundles, special low pressure loss layout |